Product Identification

Product ID:CELITE 545
MSDS Date:05/07/1991
FSC:9390
NIIN:01-280-8621
MSDS Number: BPQYR

Responsible Party
MANVILLE SALES CORP
717 17TH ST
DENVER, CO 80127-5108
US

Emergency Phone: 303-978-4900

Info Phone: 303-978-2000

Preparer: RICHARD A. VERSEN

Cage: 75165

Contractor
SCHULLER INTERNATIONAL INC.
5108 DENVER, CO 80217-5108 US

Telephone: 303-978-4900

Cage: 75165

Ingredients

FLUX CALCINED DIATOMACEOUS EARTH (DE)

CAS: 68855-54-9

Fraction By Weight: 100%

OSHA PEL 10 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


SILICA, CRYSTALLINE - CRISTOBALITE

CAS: 14464-46-1

RTECS: VV7325000

Fraction By Weight: <60%

OSHA PEL SEE TABLE Z3

ACGIH TLV: 0.05 MG/M3 RDUST9293


SILICA, CRYSTALLINE - QUARTZ

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: <3%

OSHA PEL SEE TABLE Z3

ACGIH TLV: 0.1 MG/M3 RDUST;9293

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: UPPER RESPIRATORY AND MINOR EYE
IRRITATION. CHRONIC: IS A KNOWN CAUSE OF SILICOSIS, A NONCANCEROUS
LUNG DISEASE CAUSED BY EXCESSIVE EXPOSURE TO CRYSTALLINE SILICA.
Explanation of Carcinogenicity:CRYSTALLINE SILICA/CRYSTALLINE SILICA
(CRISTOBALITE): GROUP 2A (IARC), ANTICIPATED TO BE A CARCINOGEN
(NTP).
Effects of Overexposure:INHALATION: IRRITATION OR SORENESS IN THROAT &
NOSE. IN EXTREME EXPOSURES SOME CONGESTION MAY OCCUR. EYES:
TEMPORARY MECHANICAL IRRITATION OR REDNESS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. DRINK WATER TO CLEAR THROAT
AND BLOW NOSE TO EVACUATE DUST. SKIN: FLUSH WITH COPIOUS AMOUNTS OF
WATER . INGESTION: CALL MD IMMEDIATELY . EYES: FLUSH EYES W ITH
LARGE AMOUNTS OF WATER FOR AT LEAST15 MINUTES. IF IRRITATION
PERSISTS, CONSULT PHYSICIAN.

Fire Fighting

Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:SHOVEL OR SWEEP UP (WITH AID OF DUST
SUPPRESSANT SUCH AS WATER.) VACUUM CLEAN REMAINING FINE PARTICLES.
UNCONTAMINATED MATERIAL MAY BE REUSED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID CREATING DUSTS. MAINTAIN GOOD
HOUSEKEEPING PRACTICES AND REPAIR BROKEN BAGS IMMEDIATELY.
Other Precautions:ADEQUATE VENTILATION TO KEEP DUST EXPOSURE LEVELS
BELOW PEL/TLV.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATORY PROTECTION
AS INDICATED: <10X PEL NIOSH/MSHA APPROVED HALF MASK; <100X PEL
NIOSH/MSHA APPROVED FULL-FACE; <200X PEL NIOSH/MSHA APPROVED TYPE C
SUPPLIED AIR (CONTINU OUS FLOW MODE).
Ventilation:LOCAL EXHAUST VENTILATION MAY BE REQUIRED IN DUST
GENERATING OPERATIONS TO KEEP DUST CONCENTRATIONS BELOW PEL/TLV.
Protective Gloves:COTTON GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT APPLICABLE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Spec Gravity:2.3 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:FINE WHITE POWDER, NO ODOR.
Percent Volatiles by Volume:NIL

Stability

Stability Indicator/Materials to Avoid:YES
HYDROFLUORIC ACID.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:NON-HAZARDOUS AS DEFINED BY RCRA (40 CFR 261).
DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS
.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their